If you buy HPLC columns, you have seen both names on the same box. So people ask a fair question. Is Purospher STAR fighting against LiChroCART? Or are they the same thing?
Here is the short answer. They are not rivals. They are two different parts of one column. LiChroCART is the shape and hardware of the column. Purospher STAR is the material inside that does the real work. Many columns are sold as both at once, like "Purospher STAR RP-18 LiChroCART 125-3."
This post makes the difference clear. Then it helps you pick the right setup for your method.
Purospher STAR is a packing material. This is the tiny powder that fills the column. In HPLC, this powder is called the stationary phase. Your sample flows through it and gets pulled apart into clean, separate peaks.
Purospher STAR is made from high-purity silica. It is metal-free. That low metal level is a big deal. Metal traces cause bad peak shape, tailing, and messy results. Because Purospher STAR keeps metals low, you get sharp peaks and steady runs.
A few key facts:
In plain words, Purospher STAR is the "engine." It decides how well your compounds split apart.
LiChroCART is not a packing. It is the column format. Think of it as the body and holder system.
A LiChroCART column is a cartridge. A cartridge is a small tube of packing with no end fittings of its own. You cannot run it alone. You slide it into a holder called manuCART. The holder seals it and lets you connect it to your HPLC system.
But there is one limit to know. A LiChroCART cartridge in a manuCART holder is hand-tight only. So it has a pressure ceiling of about 250 bar. If your method runs at very high pressure, this format may not fit.
Since Purospher STAR is the packing and LiChroCART is the format, the true decision has two parts.
Part 1: Pick your phase (the packing). Here the real comparison is Purospher STAR against older Merck phases like LiChrospher. Purospher STAR is the newer, higher-purity option. It gives better peak shape and works at higher pH. LiChrospher is an older classic phase and is still used in many set methods.
Part 2: Pick your format (the hardware). Here the real comparison is LiChroCART against Hibar. LiChroCART is the cartridge format with a pressure limit near 250 bar. Hibar RT is a ready-to-use column with fittings built in. Hibar handles higher pressure. So Hibar suits fast methods and UHPLC-style work.
Purospher STAR vs LiChroCART at a glance
Point | Purospher STAR | LiChroCART | What it is | The packing (stationary phase) | The column format (cartridge + holder) | Main job | Separates your compounds | Holds the packing and connects to the system | Common types | RP-18, RP-8, NH2 | Cartridge sizes like 125-3, 250-4 | Pressure limit | Set by the format used | About 250 bar (hand-tight) | Best when | You need sharp peaks and steady runs | You want low-cost cartridge swaps
The main thing to remember: you do not choose one over the other. You choose a phase and a format together.
Use these simple checks.
Choose Purospher STAR (as your phase) when:
Choose the LiChroCART format when:
Skip the LiChroCART format and pick Hibar when:
For most standard reversed phase work in a pharma QC lab, a Purospher STAR RP-18 in a LiChroCART cartridge is a strong, safe pick. It gives good peaks and keeps costs down.
A quick example
Say you run a simple assay for a drug tablet. Your pressure sits near 180 bar. You want sharp peaks and low cost.
A Purospher STAR RP-18 endcapped cartridge in LiChroCART format works well here. You get the clean peaks from the phase. You get the low running cost from the cartridge system. And 180 bar is safely under the 250 bar limit.
Now say you switch to a fast method at 400 bar. The LiChroCART format cannot take that. You keep the Purospher STAR phase but move to a Hibar format. Same great peaks, but now the hardware can handle the pressure.
No. Purospher STAR is the packing inside the column. LiChroCART is the cartridge format that holds a packing. They often come together in one product.
Yes. The same Purospher STAR phase is also sold in the Hibar format, which has its own fittings and a higher pressure limit.
Only for LiChroCART cartridges. The cartridge has no fittings, so it needs the holder to seal and connect.
About 250 bar when hand-tight in a manuCART holder. For higher pressure, choose Hibar.
Purospher STAR is a good choice. Its high-purity, metal-free silica helps stop tailing with basic compounds.